{"title":"ABC Dry Chemical Fire Extinguishers","description":"\u003cp\u003eABC dry chemical is the one agent rated for all three common fire classes, so a single cylinder covers ordinary combustibles, flammable liquids, and energized electrical equipment. That is why it is the default choice for offices, warehouses, schools, and mixed-occupancy buildings. We stock Buckeye ABC units in three wall-hook sizes, made in Kings Mountain, North Carolina.\u003c\/p\u003e\n\u003ch3\u003ePicking a size\u003c\/h3\u003e\n\u003cp\u003eSize is set by the hazard and by how far someone has to walk to reach an extinguisher. \u003ca href=\"\/resources\/building-codes-standards\/fire-extinguisher-standards\/nfpa-10\"\u003eNFPA 10\u003c\/a\u003e sets the travel-distance and placement rules that decide how many units a floor needs and what rating each one carries.\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eUL rating\u003c\/th\u003e\n\u003cth\u003eCommon use\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e5 lb\u003c\/td\u003e\n\u003ctd\u003e3-A:40-B:C\u003c\/td\u003e\n\u003ctd\u003eOffices, retail, classrooms, light commercial\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e10 lb\u003c\/td\u003e\n\u003ctd\u003e4-A:80-B:C\u003c\/td\u003e\n\u003ctd\u003eCommercial buildings, schools, plants, warehouses\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e20 lb\u003c\/td\u003e\n\u003ctd\u003e10-A:120-B:C\u003c\/td\u003e\n\u003ctd\u003eWarehouses, manufacturing, mechanical and boiler rooms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll three are listed under \u003ca href=\"\/resources\/building-codes-standards\/fire-extinguisher-standards\/ul-299\"\u003eANSI\/UL 299\u003c\/a\u003e, the standard for dry chemical extinguishers.\u003c\/p\u003e\n\u003ch3\u003eMounting and cabinets\u003c\/h3\u003e\n\u003cp\u003eEach unit ships with a wall hook. Where the extinguisher would stick out into a corridor or take abuse, a cabinet is the usual answer. See \u003ca href=\"\/resources\/building-codes-standards\/fire-extinguisher-standards\/fire-extinguisher-mounting-requirements\"\u003emounting height and clearance requirements\u003c\/a\u003e, or browse \u003ca href=\"\/safety\/fire-extinguishers\/cabinets\"\u003efire extinguisher cabinets\u003c\/a\u003e sized to match.\u003c\/p\u003e\n\u003ch3\u003eDo these meet DOT requirements for commercial vehicles?\u003c\/h3\u003e\n\u003cp\u003eYes. All three sizes carry a UL rating that satisfies \u003ca href=\"\/resources\/guides\/dot-fire-extinguisher-requirements-commercial-vehicles\"\u003eDOT 49 CFR 393.95\u003c\/a\u003e for commercial motor vehicles, including the 10 B:C minimum for placarded hazmat loads. For vehicle use you will usually want a bracket rather than the wall hook.\u003c\/p\u003e\n\u003ch3\u003eWhen is ABC the wrong choice?\u003c\/h3\u003e\n\u003cp\u003eThe monoammonium phosphate powder is corrosive and leaves a residue that keeps damaging electronics after the fire is out, so server rooms and equipment closets are better served by a clean agent. Cooking-oil fires need a Class K wet chemical unit, not ABC. For flammable-liquid hazards specifically, our \u003ca href=\"\/resources\/guides\/class-b-fire-extinguisher-guide\"\u003eClass B fire extinguisher guide\u003c\/a\u003e compares ABC against CO2 and Purple K.\u003c\/p\u003e","products":[{"product_id":"abc-dry-chemical-fire-extinguisher-w-wall-hook-20-lb","title":"Buckeye ABC Dry Chemical Fire Extinguisher w\/ Wall Hook – 20 lb.","description":"\u003cp\u003eThe \u003ca href=\"https:\/\/usmadesupply.com\/companies\/buckeye\"\u003eBuckeye\u003c\/a\u003e 20 lb ABC dry chemical fire extinguisher (10-A:120-B:C) is a high-capacity size for warehouses, manufacturing, mechanical and boiler rooms, and other higher-hazard commercial areas. It also meets \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/dot-cfr-393-95\"\u003eDOT 49 CFR §393.95\u003c\/a\u003e for heavy-duty and high-risk vehicle applications. The monoammonium phosphate agent fights Class A, B, and C fires. It is not recommended for use on sensitive electronics or computers.\u003c\/p\u003e\u003cp\u003eMade in the USA by Buckeye in Kings Mountain, North Carolina. Supports Buy American and domestic-preference procurement on public projects.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL\/ULC rating:\u003c\/strong\u003e 10-A:120-B:C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgent:\u003c\/strong\u003e 20 lb monoammonium phosphate (ABC dry chemical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 21.25 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 8.75 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCylinder diameter:\u003c\/strong\u003e 7.5 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge time and range:\u003c\/strong\u003e 27 seconds, 15 to 21 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weight:\u003c\/strong\u003e 33.5 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -65°F to 120°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Polyester epoxy powder-coated steel cylinder, anodized all-metal valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e UL and ULC Listed; \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/ul-299\"\u003eANSI\/UL 299\u003c\/a\u003e and \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/ul-711\"\u003eANSI\/UL 711\u003c\/a\u003e; DOT compliant; US Coast Guard approved with mounting bracket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Made in the USA (Kings Mountain, NC)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding placement (NFPA 10)\u003c\/h4\u003e\u003cp\u003eIn commercial buildings, portable fire extinguisher placement follows \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/nfpa-10\"\u003eNFPA 10\u003c\/a\u003e, not the DOT vehicle rules below. Every point on the floor must be within \u003cstrong\u003e75 ft\u003c\/strong\u003e of a Class A extinguisher. Its gross weight of 33.5 lb is under 40 lb, so mount it with the top no more than \u003cstrong\u003e5 ft\u003c\/strong\u003e above the floor and at least \u003cstrong\u003e4 in\u003c\/strong\u003e of floor clearance (NFPA 10 §6.1.3.8). A 10-A unit is common where the fire load is high; the required size and count are set by your authority having jurisdiction (AHJ).\u003c\/p\u003e\u003ch4\u003eCabinet fit\u003c\/h4\u003e\u003cp\u003eAt \u003cstrong\u003e7-1\/2 in diameter\u003c\/strong\u003e, this 20 lb unit does not fit a standard 10 lb extinguisher cabinet, which is only about 5-3\/4 in deep. Wall-hook mount it in the open, or use a cabinet sized for a 20 lb extinguisher. Contact us to confirm fit for a specific cabinet.\u003c\/p\u003e\n\u003c!-- buckeye-dot-rec v1 start --\u003e\n\u003ch4\u003eDOT Vehicle Size Recommendations\u003c\/h4\u003e\n\u003cp\u003eDOT 49 CFR §393.95 requires commercial motor vehicles to carry a UL-listed fire extinguisher. Minimum size depends on vehicle class and whether the load is placarded hazmat.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eUL Rating\u003c\/th\u003e\n\u003cth\u003eRecommended For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5 lb\u003c\/td\u003e\n\u003ctd\u003e1-A:10-B:C\u003c\/td\u003e\n\u003ctd\u003ePickups, light service vehicles, CMVs under 10,001 lb GVWR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 lb\u003c\/td\u003e\n\u003ctd\u003e3-A:40-B:C\u003c\/td\u003e\n\u003ctd\u003eSemi-trucks, box trucks, flatbeds, buses (standard CMVs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 lb\u003c\/td\u003e\n\u003ctd\u003e4-A:80-B:C\u003c\/td\u003e\n\u003ctd\u003ePlacarded hazmat transport, tanker trucks, large fleets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e\u003cstrong\u003e20 lb\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003e\u003cstrong\u003e10-A:120-B:C\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003e\u003cstrong\u003eHeavy-duty extended-fire scenarios, high-risk cargo\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSee the full \u003ca href=\"https:\/\/usmadesupply.com\/resources\/guides\/dot-fire-extinguisher-requirements-commercial-vehicles\"\u003eDOT fire extinguisher requirements guide\u003c\/a\u003e for hazmat rules, mounting specifications, and inspection intervals.\u003c\/p\u003e\n\u003c!-- buckeye-dot-rec v1 end --\u003e","brand":"Buckeye","offers":[{"title":"ABC Dry Chemical Fire Extinguisher w\/ Wall Hook – 20 lb.","offer_id":44771924082865,"sku":"r\u0026r|BE-12120","price":155.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/12120-12121-20lb-ABC-Extinguisher.jpg?v=1773251006"},{"product_id":"abc-dry-chemical-fire-extinguisher-w-wall-hook-5-lb","title":"Buckeye ABC Dry Chemical Fire Extinguisher w\/ Wall Hook – 5 lb.","description":"\u003cp\u003eThe \u003ca href=\"https:\/\/usmadesupply.com\/companies\/buckeye\"\u003eBuckeye\u003c\/a\u003e 5 lb ABC dry chemical fire extinguisher (3-A:40-B:C) is a compact, easy-to-handle size for offices, retail, classrooms, and light commercial spaces. It also meets \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/dot-cfr-393-95\"\u003eDOT 49 CFR §393.95\u003c\/a\u003e for standard commercial vehicles such as semis, box trucks, and buses. The monoammonium phosphate agent fights \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/ul-711#fire-classifications\"\u003eClass A, B, and C fires\u003c\/a\u003e. It is not recommended for use on sensitive electronics or computers.\u003c\/p\u003e\u003cp\u003eMade in the USA by Buckeye in Kings Mountain, North Carolina. Supports Buy American and domestic-preference procurement on public projects.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL\/ULC rating:\u003c\/strong\u003e 3-A:40-B:C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgent:\u003c\/strong\u003e 5 lb monoammonium phosphate (ABC dry chemical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16.375 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.25 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCylinder diameter:\u003c\/strong\u003e 4.25 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge time and range:\u003c\/strong\u003e 14 seconds, 12 to 18 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weight:\u003c\/strong\u003e 10 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -65°F to 120°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Polyester epoxy powder-coated steel cylinder, anodized all-metal valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e UL and ULC Listed; \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/ul-299\"\u003eANSI\/UL 299\u003c\/a\u003e and \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/ul-711\"\u003eANSI\/UL 711\u003c\/a\u003e; DOT compliant; US Coast Guard approved with mounting bracket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Made in the USA (Kings Mountain, NC)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding placement (NFPA 10)\u003c\/h4\u003e\u003cp\u003eIn commercial buildings, portable fire extinguisher placement follows \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/nfpa-10\"\u003eNFPA 10\u003c\/a\u003e, not the DOT vehicle rules below. Every point on the floor must be within \u003cstrong\u003e75 ft\u003c\/strong\u003e of a Class A extinguisher. Mount the unit with its top no more than \u003cstrong\u003e5 ft\u003c\/strong\u003e above the floor and at least \u003cstrong\u003e4 in\u003c\/strong\u003e of floor clearance (NFPA 10 §6.1.3.8). A 2-A or larger extinguisher within 75 ft covers most light-hazard areas, but the required size and count are set by your authority having jurisdiction (AHJ).\u003c\/p\u003e\u003ch4\u003eCabinet fit\u003c\/h4\u003e\u003cp\u003eAt \u003cstrong\u003e4-1\/4 in diameter\u003c\/strong\u003e and 16-3\/8 in tall, it fits virtually any standard semi-recessed extinguisher cabinet, including both 5 lb and 10 lb cabinet tubs, with room to spare.\u003c\/p\u003e\n\u003c!-- buckeye-dot-rec v1 start --\u003e\n\u003ch4\u003eDOT Vehicle Size Recommendations\u003c\/h4\u003e\n\u003cp\u003eDOT 49 CFR §393.95 requires commercial motor vehicles to carry a UL-listed fire extinguisher. Minimum size depends on vehicle class and whether the load is placarded hazmat.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eUL Rating\u003c\/th\u003e\n\u003cth\u003eRecommended For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5 lb\u003c\/td\u003e\n\u003ctd\u003e1-A:10-B:C\u003c\/td\u003e\n\u003ctd\u003ePickups, light service vehicles, CMVs under 10,001 lb GVWR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 lb\u003c\/td\u003e\n\u003ctd\u003e3-A:40-B:C\u003c\/td\u003e\n\u003ctd\u003eSemi-trucks, box trucks, flatbeds, buses (standard CMVs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 lb\u003c\/td\u003e\n\u003ctd\u003e4-A:80-B:C\u003c\/td\u003e\n\u003ctd\u003ePlacarded hazmat transport, tanker trucks, large fleets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 lb\u003c\/td\u003e\n\u003ctd\u003e10-A:120-B:C\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty extended-fire scenarios, high-risk cargo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSee the full \u003ca href=\"https:\/\/usmadesupply.com\/resources\/guides\/dot-fire-extinguisher-requirements-commercial-vehicles\"\u003eDOT fire extinguisher requirements guide\u003c\/a\u003e for hazmat rules, mounting specifications, and inspection intervals.\u003c\/p\u003e\n\u003c!-- buckeye-dot-rec v1 end --\u003e","brand":"Buckeye","offers":[{"title":"ABC Dry Chemical Fire Extinguisher w\/ Wall Hook – 5 lb.","offer_id":44771924345009,"sku":"r\u0026r|BE-10914","price":56.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/10914-5lb-ABC-Extinguisher-1200.jpg?v=1785454919"},{"product_id":"abc-dry-chemical-fire-extinguisher-w-wall-hook-10-lb","title":"Buckeye ABC Dry Chemical Fire Extinguisher w\/ Wall Hook – 10 lb.","description":"\u003cp\u003eThe \u003ca href=\"https:\/\/usmadesupply.com\/companies\/buckeye\"\u003eBuckeye\u003c\/a\u003e 10 lb ABC dry chemical fire extinguisher (4-A:80-B:C) is the most common size for commercial buildings such as offices, schools, plants, and warehouses. It also meets \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/dot-cfr-393-95\"\u003eDOT 49 CFR §393.95\u003c\/a\u003e for placarded and hazmat vehicles and large fleets. The monoammonium phosphate agent fights Class A (ordinary combustibles), B (flammable liquids), and C (energized electrical) fires. It is not recommended for use on sensitive electronics or computers.\u003c\/p\u003e\u003cp\u003eMade in the USA by Buckeye in Kings Mountain, North Carolina. Supports Buy American and domestic-preference procurement on public projects.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL\/ULC rating:\u003c\/strong\u003e 4-A:80-B:C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgent:\u003c\/strong\u003e 10 lb monoammonium phosphate (ABC dry chemical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 21 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.75 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCylinder diameter:\u003c\/strong\u003e 5.125 in (5-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge time and range:\u003c\/strong\u003e 22 seconds, 15 to 21 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weight:\u003c\/strong\u003e 18.25 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -65°F to 120°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Polyester epoxy powder-coated steel cylinder, anodized all-metal valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e UL and ULC Listed; \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/ul-299\"\u003eANSI\/UL 299\u003c\/a\u003e and \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/ul-711\"\u003eANSI\/UL 711\u003c\/a\u003e; DOT compliant; US Coast Guard approved with mounting bracket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Made in the USA (Kings Mountain, NC)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding placement (NFPA 10)\u003c\/h4\u003e\u003cp\u003eIn commercial buildings, portable fire extinguisher placement follows \u003ca href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/fire-extinguisher-standards\/nfpa-10\"\u003eNFPA 10\u003c\/a\u003e, not the DOT vehicle rules below. Every point on the floor must be within \u003cstrong\u003e75 ft\u003c\/strong\u003e of a Class A extinguisher. Mount the unit with its top no more than \u003cstrong\u003e5 ft\u003c\/strong\u003e above the floor and at least \u003cstrong\u003e4 in\u003c\/strong\u003e of floor clearance (NFPA 10 §6.1.3.8). The required size and count depend on your occupancy’s hazard classification, which is set by your authority having jurisdiction (AHJ).\u003c\/p\u003e\u003ch4\u003eCabinet fit\u003c\/h4\u003e\u003cp\u003eIts standard \u003cstrong\u003e5-1\/8 in cylinder\u003c\/strong\u003e fits standard semi-recessed 10 lb extinguisher cabinets, for example the JL Industries \/ Embassy 5614-series with a 5-3\/4 in tub. The wider 6 in diameter \"Short\" 10 lb models do not fit these cabinets.\u003c\/p\u003e\n\u003c!-- buckeye-dot-rec v1 start --\u003e\n\u003ch4\u003eDOT Vehicle Size Recommendations\u003c\/h4\u003e\n\u003cp\u003eDOT 49 CFR §393.95 requires commercial motor vehicles to carry a UL-listed fire extinguisher. Minimum size depends on vehicle class and whether the load is placarded hazmat.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eUL Rating\u003c\/th\u003e\n\u003cth\u003eRecommended For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5 lb\u003c\/td\u003e\n\u003ctd\u003e1-A:10-B:C\u003c\/td\u003e\n\u003ctd\u003ePickups, light service vehicles, CMVs under 10,001 lb GVWR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 lb\u003c\/td\u003e\n\u003ctd\u003e3-A:40-B:C\u003c\/td\u003e\n\u003ctd\u003eSemi-trucks, box trucks, flatbeds, buses (standard CMVs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e\u003cstrong\u003e10 lb\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003e\u003cstrong\u003e4-A:80-B:C\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003e\u003cstrong\u003ePlacarded hazmat transport, tanker trucks, large fleets\u003c\/strong\u003e\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 lb\u003c\/td\u003e\n\u003ctd\u003e10-A:120-B:C\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty extended-fire scenarios, high-risk cargo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSee the full \u003ca href=\"https:\/\/usmadesupply.com\/resources\/guides\/dot-fire-extinguisher-requirements-commercial-vehicles\"\u003eDOT fire extinguisher requirements guide\u003c\/a\u003e for hazmat rules, mounting specifications, and inspection intervals.\u003c\/p\u003e\n\u003c!-- buckeye-dot-rec v1 end --\u003e","brand":"Buckeye","offers":[{"title":"ABC Dry Chemical Fire Extinguisher w\/ Wall Hook – 10 lb.","offer_id":44771924639921,"sku":"r\u0026r|BE-11340","price":90.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/11340-11341-10lb-ABC-Extinguisher.jpg?v=1773250567"}],"url":"https:\/\/shop.usmadesupply.com\/collections\/abc-dry-chemical.oembed","provider":"US Made Supply","version":"1.0","type":"link"}