{"title":"Access Control Power Supplies","description":"\u003cp\u003eAn access control power supply turns building power into the low voltage DC that electrified door hardware runs on: electric strikes, magnetic locks, electrified exit devices, card readers and the relays that tie them together. It usually mounts in a steel enclosure near the doors it serves.\u003c\/p\u003e\n\u003cp\u003eSize it to the hardware. Add up what each device draws at its voltage, and allow for inrush: some electrified exit devices draw a short surge when they pull the latch back. Relay and distribution boards split and switch the output between doors. Battery backup keeps the hardware working through a power cut. A fire alarm interface releases locks when the alarm signals, which many locked egress doors must do. Our \u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/delayed-egress-locking\"\u003edelayed egress locking guide\u003c\/a\u003e covers one case. See also \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/electric-strikes\"\u003eelectric strikes\u003c\/a\u003e and \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/magnetic-locks\"\u003emagnetic locks\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat listing should an access control power supply have?\u003c\/h3\u003e\n\u003cp\u003eUL 294 covers access control system units, and power supplies for these systems are commonly listed to it. A Class 2 output limits the energy on the low voltage wiring. Each product page lists its own certifications, so check them against your specification.\u003c\/p\u003e","products":[{"product_id":"allegion-ps902-ps904-and-ps914-access-control-power-supplies-12-or-24-vdc","title":"Allegion PS902 PS904 and PS914 Access Control Power Supplies 12 or 24 VDC","description":"\u003cp\u003eThe Allegion PS900 series are low voltage power supplies for electrified door hardware: electric strikes, magnetic locks, electrified exit devices and card readers. Allegion sells the PS902 and PS904 under its Schlage name and the PS914 under \u003ca href=\"\/companies\/von-duprin\"\u003eVon Duprin\u003c\/a\u003e, and Von Duprin's electrified products catalog lists them for its exit devices. Each takes 120 to 240 VAC and puts out filtered, regulated Class 2 power at 12 or 24 VDC, set with a jumper. The PS902 delivers 2 A and the PS904 4 A. The PS914 delivers 4 A and is the one Von Duprin designs for electrified panic devices that draw a high in-rush current. Each comes in a steel enclosure with a hinged cover and room for plug-in option boards, a fire alarm interface and backup batteries, all ordered separately.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS902, PS904 or PS914 base power supply. Selected above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS902 2 A, PS904 4 A, PS914 4 A, at 12 or 24 VDC, field selectable with a jumper. Constant output rating at both voltages. Class 2, filtered and regulated. Switching supply, 5 percent regulation, ripple 240 mV peak to peak maximum (PS902 and PS904) or 360 mV (PS914)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 to 240 VAC, 50\/60 Hz, universal, with a fused primary input and a protective cover over the high voltage circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC input and DC output monitoring with LED indicators. An AC input indicator visible from outside the cabinet, with isolated SPDT contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption boards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS902 has one option board connector, PS904 and PS914 have two. Von Duprin's boards: 900-2RS (two relays, single or pair door sequencing), 900-4R (four relays), 900-4RL (four relays with logic for interlocks, auto operators and time delay), 900-8F (eight fused outputs) and 900-8P (eight PTC protected outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire alarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional 900-FA plug-in board. Outputs can be set to cut power or keep power when the fire alarm signals. On the PS904 and PS914 it mounts on an option board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional 900-BB backup board, or the 900-BBK kit (board plus batteries). The cabinet holds one or two batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrified exit devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllegion's data sheets: the PS902 runs up to two Von Duprin QEL devices with one 900-2RS board and is not for EL devices. The PS914 runs up to eight QEL or EL devices with two 900-4RL boards, with wire run lengths limited when several EL devices share it. The PS904 data sheet gives no exit device figures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGray baked enamel steel, 14 x 12 x 4 in (H x W x D), eight 1\/2 and 3\/4 in knockouts, hinged cover with lock down screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 to 120 F (0 to 49 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eWhat else the system needs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOption boards.\u003c\/strong\u003e The base unit is the supply itself. Relay, logic and distribution boards add switching, sequencing and separately protected outputs. Pick the boards for the hardware on the job. \u003cstrong\u003eBatteries and the backup board\u003c\/strong\u003e if the hardware must keep working through a power cut. \u003cstrong\u003eThe fire alarm board\u003c\/strong\u003e if the code requires locks to release when the fire alarm signals. \u003cstrong\u003eA 120 VAC circuit\u003c\/strong\u003e and low voltage wiring to each device, by your installer. For Von Duprin EL exit devices, which draw a high in-rush current, use the PS914. Von Duprin QEL devices can run on a PS902 or PS914 fitted with the right option board, sized for the connected load and wire run.\u003c\/p\u003e\n\n\u003ch3\u003eListings\u003c\/h3\u003e\n\u003cp\u003eAllegion lists the PS900 series to ANSI\/UL 294 (access control system units), ULC-S318, RoHS and FCC Part 15, Class 2.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-files\/von-duprin-\/information-documents\/Von_Duprin_PS914_Power_Supply_Data_Sheet_104101.pdf\" rel=\"nofollow\"\u003ePS914 data sheet\u003c\/a\u003e ·\n\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-files\/schlage\/information-documents\/Schlage_PS904_Power_Supply_Data_Sheet_104194.pdf\" rel=\"nofollow\"\u003ePS904 data sheet\u003c\/a\u003e ·\n\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-files\/schlage\/information-documents\/Schlage_Power_Supplies_PS902_Data_Sheet_104195.pdf\" rel=\"nofollow\"\u003ePS902 data sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Von Duprin","offers":[{"title":"PS902: 2 A","offer_id":48016358703281,"sku":"PS902","price":273.0,"currency_code":"USD","in_stock":true},{"title":"PS904: 4 A","offer_id":48016358736049,"sku":"PS904","price":495.0,"currency_code":"USD","in_stock":true},{"title":"PS914: 4 A, high in-rush for EL exit devices","offer_id":48016523526321,"sku":"PS914","price":829.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/0_4eb12487-54f2-4a59-a7a7-0df9bab1563c.webp?v=1791687101"},{"product_id":"sdc-600-series-access-control-power-supply","title":"SDC 600 Series Access Control Power Supply","description":"\u003cp\u003eThe \u003ca href=\"\/companies\/security-door-controls\"\u003eSDC\u003c\/a\u003e 602RF is a 1 A access control power supply, one of SDC's 600 Series power controllers: regulated and filtered linear DC power at 12 or 24 VDC, field selectable, with a Class 2 output, in a 10 x 10 x 4 in cabinet. It powers electric locks, magnetic locks, electric latch retraction kits and access control equipment, charges backup batteries, and has a fire alarm input that SDC says releases all fail safe locks and door holders at once. See all our \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/access-control-power-supplies\"\u003eaccess control power supplies\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e602RF, SDC's 1 A DC power controller with cabinet. This is the base model: SDC's options (230 VAC input, cover status light, key lock cover, 6 ft power cord, fire\/emergency release manual reset switch, on\/off switches) and door control boards are separate builds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 VAC, 0.8 A maximum, 50\/60 Hz, wired to the AC input terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 or 24 VDC at 1 A, Class 2, set with switches on the board (turn the power off before changing them). SDC's instructions give an output range of 9.2 to 12.0 VDC at the 12 V setting and 21.2 to 24.0 VDC at 24 V, with 0.05 V maximum ripple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire alarm input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed contact from the fire alarm panel to the fire panel terminals. SDC: it provides simultaneous release of all fail safe locks and door holders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsolated charging circuit, 13.5 or 27 VDC at 250 mA, with low battery disconnect before deep discharge. Batteries not included. SDC's instructions call for 4 Ah batteries, replaced every three years; 24 VDC standby needs two 12 V batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection and status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput and output surge protection: the AC input is circuit breaker protected and the outputs PTC protected. Status light on the board: amber for system OK, red on battery power, green for no DC output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 x 10 x 4 in, 18 gauge, with knockouts on the sides for wiring and mounting holes for SDC's door control modules. The combined load of modules and hardware may not exceed the supply's rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 lb, per SDC's datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSDC's notes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot intended to power a local burglar alarm indicating device. Test the unit yearly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eWith an SDC LR100 latch retraction kit\u003c\/h3\u003e\n\u003cp\u003eSDC's LR100 datasheet names the 602RF for a single door with every LR100 kit except the Adams Rite LR100ARK and the Dor-O-Matic LR100FAK, which take SDC's 631RF, and says SDC 602 power controllers accommodate the kit's 1.5 A inrush. The LR100 runs on 24 VDC, so set the output to 24 V. For a pair of doors released together SDC specifies its 602RFUR1 or 634RF instead.\u003c\/p\u003e\n\n\u003ch3\u003eWhat else the installation needs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBackup batteries\u003c\/strong\u003e, if the doors must keep working through a power cut: none are included, though the photo shows two. \u003cstrong\u003eA 115 VAC circuit\u003c\/strong\u003e wired to the cabinet's input terminals; SDC's PC option adds a 6 ft power cord where code permits. \u003cstrong\u003eA control\u003c\/strong\u003e to switch the output to each door, such as an access control panel's relay or one of SDC's door control boards, with the combined load inside the 1 A rating. \u003cstrong\u003eThe fire alarm connection\u003c\/strong\u003e, where locks must release on alarm: a normally closed contact from the fire alarm panel to the supply's fire panel terminals.\u003c\/p\u003e\n\n\u003ch3\u003eListings\u003c\/h3\u003e\n\u003cp\u003eSDC lists the 602 Series to UL 294 (access control system units), UL 603 (power supplies for use with burglar alarm systems) and ULC-S318. SDC's installation instructions give its UL 294 performance levels: access control line security I, destructive attack I, endurance IV, standby power I.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sdcsecurity.com\/docs\/DS-602.pdf\" rel=\"nofollow\"\u003eSDC 602 Series datasheet (DS-602)\u003c\/a\u003e ·\n\u003ca href=\"https:\/\/www.sdcsecurity.com\/docs\/602RF_Installs.pdf\" rel=\"nofollow\"\u003eSDC 602RF installation instructions\u003c\/a\u003e ·\n\u003ca href=\"https:\/\/www.sdcsecurity.com\/products\/602-Series-1-Amp-Power-Controllers\" rel=\"nofollow\"\u003eSDC 602 Series product page\u003c\/a\u003e ·\n\u003ca href=\"https:\/\/www.sdcsecurity.com\/ul-listings\" rel=\"nofollow\"\u003eSDC UL listings\u003c\/a\u003e\u003c\/p\u003e","brand":"SDC","offers":[{"title":"1 A at 12 or 24 VDC (602RF)","offer_id":48106439704753,"sku":"602RF","price":284.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/0_01d23fbe-a48b-4c78-a0a6-06f76096ef6a.webp?v=1793202512"}],"url":"https:\/\/shop.usmadesupply.com\/collections\/access-control-power-supplies.oembed","provider":"US Made Supply","version":"1.0","type":"link"}