{"title":"Flush Bolts and Strikes","description":"\u003cp\u003eOn a pair of doors, one leaf usually stays shut while the other is used, and the active leaf latches into it. Flush bolts hold that inactive leaf in place. They are set into the edge of the door, flush with it: a top bolt projects into the head of the frame and a bottom bolt into a strike in the floor or threshold.\u003c\/p\u003e\n\u003cp\u003eManual flush bolts are thrown by hand. Automatic flush bolts extend on their own when the active leaf closes against the inactive one and retract when it opens, so the pair also needs a coordinator, which makes sure the inactive leaf closes first. Flush bolts are made for wood doors or for hollow metal doors, and the door has to be prepared for the one you choose. A dust proof strike in the floor has a spring loaded plunger that rises to fill the strike hole whenever the bolt is up, so dirt cannot collect in it.\u003c\/p\u003e\n\u003ch3\u003eWhich flush bolts can go on a pair of fire doors?\u003c\/h3\u003e\n\u003cp\u003eIt depends on how the pair is used. Under \u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-80\"\u003eNFPA 80\u003c\/a\u003e, where both leaves of a fire rated pair are needed for exit, both get labeled fire exit hardware. Where a pair is needed for moving equipment and its inactive leaf is not needed for exit, that leaf may take labeled self-latching or automatic top and bottom flush bolts, and labeled manual bolts only where the authority having jurisdiction approves them. The door's listing, the edition your jurisdiction adopted and the authority having jurisdiction decide what the opening needs.\u003c\/p\u003e\n\u003ch3\u003eCan manual flush bolts go on an exit door?\u003c\/h3\u003e\n\u003cp\u003eOnly where the adopted code allows them. A door in a means of egress has to open without a key, a tool or special knowledge. The IBC allows manual bolts on the inactive leaf of a pair only in specific occupancies and conditions, and then only where that leaf has no knob, panic hardware or similar operating hardware. NFPA 101 generally requires each leaf needed for exit to release on its own, or approved automatic flush bolts arranged as it specifies. See \u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-101\"\u003eNFPA 101\u003c\/a\u003e and \u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/ibc-chapter-10\"\u003eIBC Chapter 10\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"ives-fb41p-automatic-flush-bolt-set-for-wood-doors-satin-stainless","title":"Ives FB41P Automatic Flush Bolt Set for Wood Doors Satin Stainless","description":"\u003cp\u003eThe \u003ca href=\"\/companies\/ives\"\u003eIves\u003c\/a\u003e FB41P is a set of two automatic flush bolts, one top and one bottom, for the inactive leaf of a pair of wood doors. They are fully automatic: closing the active door pushes the bolts out into the head of the frame and the floor strike, latching the inactive door, and opening it retracts them. The top bolt has no spring tension, so the set works with little force, and it is non-handed. For hollow metal doors, Ives makes the FB31P, which we quote. See all our \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/flush-bolts-and-strikes\"\u003eflush bolts and strikes\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFB41P-WD, top and bottom bolt, satin stainless steel 630 (US32D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWood doors only. Fits DHI W5 door and frame preparation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBolt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4 in throw, 7\/8 in vertical adjustment, 3\/4 in backset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBody 1 x 8-1\/2 x 2 in, guide 1 x 6 in, strike 15\/16 x 2-1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 10C listed for 90 minute fire doors up to 8 x 8 ft when the top and bottom bolts are both used, per Ives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLonger top rods for openings that are not fire rated, and security pin screws, by quote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eWhat else the pair of doors needs\u003c\/h3\u003e\n\u003cp\u003eA coordinator, so the inactive door always closes before the active one. Ives' instructions say to install the coordinator before the flush bolts, and size it to the active door width plus about half the inactive door width: a pair of 3 ft doors takes Ives' COR52. We quote coordinators. For the bottom bolt, Ives' DP1 or DP2 dust proof strike keeps the strike hole clean: see our \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/flush-bolts-and-strikes\"\u003eflush bolts and strikes\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eInstalling\u003c\/h3\u003e\n\u003cp\u003eIves recommends 1\/8 in between the two doors and allows at most a 3\/4 in undercut. The rub plates go on the edge of the active door, on the cam centerlines. On a fire rated pair, the door's listing and \u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-80\"\u003eNFPA 80\u003c\/a\u003e decide what the inactive leaf needs: Ives' rating requires both bolts.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.iveshardware.com\/en\/products\/flush-bolts-strikes-coordinators\/automatic-flush-bolts.html\" rel=\"nofollow\"\u003eIves automatic flush bolts product page\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-documents-2\/Template\/Ives_FB41_Automatic_Flush_Bolt_Installation_Template_101739.pdf\" rel=\"nofollow\"\u003eIves FB41 installation instructions\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-documents-2\/Template\/Ives_COR32_COR42_COR52_COR60_COR72_Coordinator_Installation_Instructions_101706.pdf\" rel=\"nofollow\"\u003eIves COR coordinator instructions\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-documents-2\/Catalog\/IVES_Architectural_Hardware_Products_Catalog_105313.pdf\" rel=\"nofollow\"\u003eIves architectural hardware catalog\u003c\/a\u003e\u003c\/p\u003e","brand":"Ives","offers":[{"title":"Default Title","offer_id":48051626410161,"sku":"FB41PWDUS32D","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/0_164fb9b0-797e-454d-a11e-307f7b19282d.webp?v=1792177697"},{"product_id":"ives-dp1-or-dp2-dust-proof-strike-for-flush-bolts","title":"Ives DP1 or DP2 Dust Proof Strike for Flush Bolts","description":"\u003cp\u003eAn \u003ca href=\"\/companies\/ives\"\u003eIves\u003c\/a\u003e DP1 or DP2 dust proof strike receives the bottom bolt of a flush bolt. Its spring loaded plunger comes back up to floor or threshold level whenever the bolt is retracted, so the strike hole cannot fill with dirt and does not need cleaning. Ives designs both for the bottom bolt of all its flush bolts. The DP1 has a round face plate and the DP2 a rectangular one; Ives lists the DP2 for a floor or a threshold. See all our \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/flush-bolts-and-strikes\"\u003eflush bolts and strikes\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDP1 or DP2, satin chrome 626 (US26D). Type selected above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrike hole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4 in diameter, 1-1\/8 in deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFasteners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-32 x 1 in flat head machine screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/BHMA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets ANSI A156.16, per Ives' product page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChanging type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIves says a DP1 can be converted to a DP2 by adding the DP2 plate package and mounting package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.iveshardware.com\/en\/products\/flush-bolts-strikes-coordinators\/dust-proof-strikes.html\" rel=\"nofollow\"\u003eIves dust proof strikes product page\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-documents-2\/Catalog\/IVES_Architectural_Hardware_Products_Catalog_105313.pdf\" rel=\"nofollow\"\u003eIves architectural hardware catalog\u003c\/a\u003e\u003c\/p\u003e","brand":"Ives","offers":[{"title":"DP2, rectangular face plate","offer_id":48051626574001,"sku":"DP2US26D","price":36.0,"currency_code":"USD","in_stock":true},{"title":"DP1, round face plate","offer_id":48051626606769,"sku":"DP1US26D","price":28.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/0_1ca56b3c-fd06-4b52-b006-f4a3c1c0a543.webp?v=1792177702"}],"url":"https:\/\/shop.usmadesupply.com\/collections\/flush-bolts-and-strikes.oembed","provider":"US Made Supply","version":"1.0","type":"link"}