{"title":"Overhead Door Stops and Holders","description":"\u003cp\u003eAn overhead door stop mounts between the top of the door and the frame and stops the door at a set opening angle, so it cannot swing into a wall, strain its hinges or overload its closer. A holder does the same and can also hold the door open. Working overhead, they stay clear of feet, carts and floor cleaning, where floor and wall stops get kicked and damaged.\u003c\/p\u003e\n\u003cp\u003eSurface models bolt to the face of the door and the frame. Concealed models are mortised into the top of the door and the frame, so they are hidden when the door is closed. Most are sized by the width of the door opening and set at installation to the angle the door should stop at. A door with a closer should also have a stop, because a closer is not made to stop the door. See \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/surface-door-closers\"\u003esurface door closers\u003c\/a\u003e and our \u003ca href=\"\/resources\/guides\/door-closer-selection-guide\"\u003edoor closer selection guide\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eCan an overhead stop go on a fire door?\u003c\/h3\u003e\n\u003cp\u003eA stop only model can, when its maker lists it for fire doors: check the product page. A mechanical hold open that a person has to release is not allowed on a fire door, because the door has to close in a fire. To hold a fire door open, use a holder that releases on the fire alarm signal, such as an \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/electromagnetic-door-holders\"\u003eelectromagnetic door holder\u003c\/a\u003e. See \u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-80\"\u003eNFPA 80\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"glynn-johnson-90s-heavy-duty-surface-overhead-door-stop-in-satin-stainless-steel","title":"Glynn-Johnson 90S Heavy Duty Surface Overhead Door Stop in Satin Stainless Steel","description":"\u003cp\u003eThe \u003ca href=\"\/companies\/glynn-johnson\"\u003eGlynn-Johnson\u003c\/a\u003e 90S is the stop-only model of the 90 Series, which Glynn-Johnson calls its most rugged holders and stops, for heavy duty applications. It stops the door at a set angle, protecting the door, frame, hinges, closer and nearby walls, and a shock absorbing spring cushions the stop. The channel is thru-bolted to the top of the door with sex bolts and the jamb bracket mounts on the face of the frame, so neither needs to be mortised in. This is 630 (US32D) satin stainless steel and non-handed. This listing has four sizes. Glynn-Johnson also makes a size 3 (903S) for openings of 27-1\/16 to 33 in.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e902S, 904S, 905S or 906S, 630 satin stainless steel. Selected above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStop only, with a shock absorbing spring that gives about 5 to 7 degrees past the stop point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStop angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSet at installation anywhere from 85 to 110 degrees with Glynn-Johnson's templates. Where a wall or another door is in the way at 110 degrees or less, Glynn-Johnson recommends dead-stop templating, set 5 to 7 degrees short of the point the door must not pass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSizing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGlynn-Johnson sizes by the door opening, measured jamb to jamb, not by the width of the door. The opening ranges here are for doors hung on butt hinges or offset pivots. Center hung doors use a different chart, so check the catalog for those.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface mounted. Channel thru-bolted to the door with sex bolts, jamb bracket on the face of the frame. For single acting doors, works with most surface applied door closers. Interior or exterior doors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90J angle jamb bracket for hinge side or flush transom mounting. 90 SHIM1, SHIM2 or SHIM3 blade stop shims (1\/4, 1\/2 or 3\/4 in). SOC: pin-in-socket security screws for the door and jamb brackets, supplied instead of the standard screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards cross reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGlynn-Johnson cross references the 902 to 906 S to BHMA C02541 (ANSI\/BHMA A156.8) and federal specification 1161A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eWhat else the opening needs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eReinforcement.\u003c\/strong\u003e Glynn-Johnson stresses that the door and frame must be reinforced to anchor an overhead stop. For metal doors and frames Glynn-Johnson recommends reinforcement at least 3\/16 in thick, 1-1\/2 in wide and 12 in long. For wood doors and frames, make sure there is enough material to anchor it. \u003cstrong\u003eA door closer, if the door has one.\u003c\/strong\u003e Glynn-Johnson recommends an overhead stop on every door with a closer, because a closer is not a door stop. See our \u003ca href=\"\/resources\/guides\/door-closer-selection-guide\"\u003edoor closer selection guide\u003c\/a\u003e. \u003cstrong\u003eA hold-open, if wanted.\u003c\/strong\u003e This is stop only. The 90H holds the door open and is a different part.\u003c\/p\u003e\n\n\u003ch3\u003eFire doors\u003c\/h3\u003e\n\u003cp\u003eGlynn-Johnson says its stop-only models are classified by UL as miscellaneous fire door accessories (category GVUX), for hollow metal or wood fire doors of any rating. Our \u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-80\"\u003eNFPA 80 guide\u003c\/a\u003e covers what may go on a fire door.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-files\/glynn-johnson\/information-documents\/Glynn-Johnson_Overhead_Door_Holders.Stops_Catalog_101401.pdf\" rel=\"nofollow\"\u003eGlynn-Johnson overhead door holders and stops catalog\u003c\/a\u003e\u003c\/p\u003e","brand":"Glynn Johnson","offers":[{"title":"Size 4: door opening 33-1\/16 to 39 in","offer_id":48016366141617,"sku":"904SUS32D","price":349.0,"currency_code":"USD","in_stock":true},{"title":"Size 2: door opening 23-1\/16 to 27 in","offer_id":48016366174385,"sku":"902SUS32D","price":349.0,"currency_code":"USD","in_stock":true},{"title":"Size 5: door opening 39-1\/16 to 45 in","offer_id":48016366207153,"sku":"905SUS32D","price":349.0,"currency_code":"USD","in_stock":true},{"title":"Size 6: door opening 45-1\/16 to 54 in","offer_id":48016366239921,"sku":"906SUS32D","price":349.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/0_a196a813-096f-44b6-ad52-495afe4d225f.webp?v=1791686813"},{"product_id":"glynn-johnson-414-concealed-overhead-door-holder-or-stop-size-4-in-satin-stainless-steel","title":"Glynn-Johnson 414 Concealed Overhead Door Holder or Stop Size 4 in Satin Stainless Steel","description":"\u003cp\u003eThe \u003ca href=\"\/companies\/glynn-johnson\"\u003eGlynn-Johnson\u003c\/a\u003e 410 Series is a concealed overhead holder and stop for medium to light duty doors. The channel is mortised into the top of the door and the jamb bracket into the frame, so when the door is closed the whole unit is hidden. When the door is open, only the arm and the jamb bracket show. The 414H holds the door open automatically at a preset angle and the 414S only stops it. Both are size 4, for door openings of 33-1\/16 to 39 in, in 630 (US32D) satin stainless steel, and non-handed.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e414H (hold open) or 414S (stop only), size 4, 630 satin stainless steel. Selected above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e414H hold open\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe hold open engages automatically when the door opens to its preset angle. It cannot be switched off, so the door is always held open there. Hold open tension adjusts with an Allen wrench. Glynn-Johnson says it meets the 250,000 test cycles required for Grade 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e414S stop only\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStops the door with a shock absorbing spring, without holding it open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAngle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSet at installation anywhere from 85 to 110 degrees with Glynn-Johnson's templates. The shock absorber gives about 5 to 7 degrees, so where a wall or another door is in the way, set the stop that much short of it (dead-stop templating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSizing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSize 4: door opening 33-1\/16 to 39 in. Glynn-Johnson sizes by the door opening, measured jamb to jamb, not by the width of the door. The opening ranges here are for doors hung on butt hinges or offset pivots. Center hung doors use a different chart, so check the catalog for those.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConcealed: channel mortised into the top of the door, jamb bracket mortised into the frame. Single or double acting doors. Works with most surface applied door closers. Interior applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSOC: pin-in-socket security screws for mounting the jamb bracket, supplied instead of the standard screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eWhat else the opening needs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoor and frame preparation.\u003c\/strong\u003e Being concealed, it needs the door and frame mortised to Glynn-Johnson's template, and its installation instructions give the mortises and mounting holes. \u003cstrong\u003eReinforcement.\u003c\/strong\u003e Glynn-Johnson stresses that the door and frame must be reinforced to anchor an overhead stop. For metal doors and frames Glynn-Johnson recommends reinforcement at least 3\/16 in thick, 1-1\/2 in wide and 12 in long. For wood doors and frames, make sure there is enough material to anchor it. \u003cstrong\u003eA door closer, if the door has one.\u003c\/strong\u003e Glynn-Johnson recommends an overhead stop on every door with a closer, because a closer is not a door stop. See our \u003ca href=\"\/resources\/guides\/door-closer-selection-guide\"\u003edoor closer selection guide\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eFire doors\u003c\/h3\u003e\n\u003cp\u003eGlynn-Johnson's catalog says its 410 Series stop only models are classified by UL as miscellaneous fire door accessories (category GVUX), for hollow metal or wood fire doors of any rating, while its installation instructions say stop only units are permitted on many fire door applications. That covers the stop only 414S: confirm it against your fire door's listing. On a wood fire door, the catalog allows it only where the door manufacturer's listing allows the cutout. The 414H's hold open is mechanical and cannot be switched off, and Glynn-Johnson's instructions say mechanical hold-open devices that require manual release are not permitted on any fire door. Our \u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-80\"\u003eNFPA 80 guide\u003c\/a\u003e covers what may go on a fire door.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-files\/glynn-johnson\/information-documents\/Glynn-Johnson_Overhead_Door_Holders.Stops_Catalog_101401.pdf\" rel=\"nofollow\"\u003eGlynn-Johnson overhead door holders and stops catalog\u003c\/a\u003e\u003c\/p\u003e","brand":"Glynn Johnson","offers":[{"title":"Hold open (414H)","offer_id":48016388161713,"sku":"414HUS32D","price":126.0,"currency_code":"USD","in_stock":true},{"title":"Stop only (414S)","offer_id":48016388194481,"sku":"414SUS32D","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/0_f3464025-d716-46e8-8409-ff9ac757a9df.webp?v=1791686816"},{"product_id":"glynn-johnson-454s-medium-duty-surface-overhead-door-stop-in-satin-stainless-steel","title":"Glynn-Johnson 454S Medium Duty Surface Overhead Door Stop in Satin Stainless Steel","description":"\u003cp\u003eThe \u003ca href=\"\/companies\/glynn-johnson\"\u003eGlynn-Johnson\u003c\/a\u003e 454S is a medium duty surface mounted overhead door stop from the 450 Series. It stops the door at a set angle with a shock absorbing spring, protecting the door, frame, hinges, closer and nearby walls. The channel is thru-bolted to the top of the door with sex bolts and the jamb bracket mounts on the face of the frame, so little preparation is needed. Size 4, for door openings of 33-1\/16 to 39 in, in 630 (US32D) satin stainless steel, non-handed.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e454S: 450 Series, size 4, stop only, 630 satin stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStop only, with a shock absorbing spring that gives about 5 to 7 degrees past the stop point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAngle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSet at installation anywhere from 85 to 110 degrees with Glynn-Johnson's templates. Where a wall or another door is in the way, use dead-stop templating, set 5 to 7 degrees short of it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSizing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSize 4: door opening 33-1\/16 to 39 in. Glynn-Johnson sizes by the door opening, measured jamb to jamb, not by the width of the door. The opening ranges here are for doors hung on butt hinges or offset pivots. Center hung doors use a different chart, so check the catalog for those.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface mounted. For single acting doors on butt hinges, offset pivots, continuous hinges, swing clear hinges and many specialty hinges. Works with most surface applied door closers, though some closers need a drop bracket from the closer maker. Interior applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450J angle jamb bracket for hinge side or flush transom mounting. Blade stop shims. SOC: pin-in-socket security screws for the channel and jamb bracket, supplied instead of the standard screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eWhat else the opening needs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eReinforcement.\u003c\/strong\u003e Glynn-Johnson stresses that the door and frame must be reinforced to anchor an overhead stop. For metal doors and frames Glynn-Johnson recommends reinforcement at least 3\/16 in thick, 1-1\/2 in wide and 12 in long. For wood doors and frames, make sure there is enough material to anchor it. \u003cstrong\u003eA door closer, if the door has one.\u003c\/strong\u003e Glynn-Johnson recommends an overhead stop on every door with a closer, because a closer is not a door stop. See our \u003ca href=\"\/resources\/guides\/door-closer-selection-guide\"\u003edoor closer selection guide\u003c\/a\u003e. \u003cstrong\u003eFor heavy use or exterior doors\u003c\/strong\u003e exposed to wind, Glynn-Johnson recommends a heavy duty holder or stop instead, such as the 90 Series.\u003c\/p\u003e\n\n\u003ch3\u003eFire doors\u003c\/h3\u003e\n\u003cp\u003eGlynn-Johnson says its stop-only models are classified by UL as miscellaneous fire door accessories (category GVUX), for hollow metal or wood fire doors of any rating. Our \u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-80\"\u003eNFPA 80 guide\u003c\/a\u003e covers what may go on a fire door.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-files\/glynn-johnson\/information-documents\/Glynn-Johnson_Overhead_Door_Holders.Stops_Catalog_101401.pdf\" rel=\"nofollow\"\u003eGlynn-Johnson overhead door holders and stops catalog\u003c\/a\u003e\u003c\/p\u003e","brand":"Glynn Johnson","offers":[{"title":"Default Title","offer_id":48016395796657,"sku":"454SUS32D","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/0_2ea49bc3-81e1-46c3-aaba-05dc875e844b.webp?v=1791686820"},{"product_id":"glynn-johnson-413s-or-415s-concealed-overhead-door-stop-in-satin-stainless-steel","title":"Glynn-Johnson 413S or 415S Concealed Overhead Door Stop in Satin Stainless Steel","description":"\u003cp\u003eThe \u003ca href=\"\/companies\/glynn-johnson\"\u003eGlynn-Johnson\u003c\/a\u003e 410 Series is a concealed overhead holder and stop for medium to light duty doors. The channel is mortised into the top of the door and the jamb bracket into the frame, so when the door is closed the whole unit is hidden. When the door is open, only the arm and the jamb bracket show. The 413S and 415S are the stop only models: they stop the door with a shock absorbing spring and do not hold it open. Size 3 or size 5, in 630 (US32D) satin stainless steel, non-handed. For size 4, see the \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/overhead-door-stops-and-holders\"\u003e414\u003c\/a\u003e among our overhead door stops and holders.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e413S (size 3) or 415S (size 5), stop only, 630 satin stainless steel. Selected above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStop only, with a shock absorbing spring that gives about 5 to 7 degrees past the stop point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAngle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSet at installation anywhere from 85 to 110 degrees with Glynn-Johnson's templates. Where a wall or another door is in the way, set the stop that much short of it (dead-stop templating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSizing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGlynn-Johnson sizes by the door opening, measured jamb to jamb, not by the width of the door. On butt hinges or offset pivots, size 3 fits openings of 27-1\/16 to 33 in and size 5 openings of 39-1\/16 to 45 in. On center hung doors the ranges move up: 33-1\/16 to 39 in for size 3 and 45-1\/16 to 51 in for size 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConcealed: channel mortised into the top of the door, jamb bracket mortised into the frame. Single or double acting doors. Works with most surface applied door closers. Interior applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSOC: pin-in-socket security screws for mounting the jamb bracket, supplied instead of the standard screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eWhat else the opening needs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoor and frame preparation.\u003c\/strong\u003e Being concealed, it needs the door and frame mortised to Glynn-Johnson's template, and its installation instructions give the mortises and mounting holes. \u003cstrong\u003eReinforcement.\u003c\/strong\u003e Glynn-Johnson stresses that the door and frame must be reinforced to anchor an overhead stop. For metal doors and frames Glynn-Johnson recommends reinforcement at least 3\/16 in thick, 1-1\/2 in wide and 12 in long. For wood doors and frames, make sure there is enough material to anchor it. \u003cstrong\u003eA door closer, if the door has one.\u003c\/strong\u003e Glynn-Johnson recommends an overhead stop on every door with a closer, because a closer is not a door stop, and its instructions say to install the stop before the closer. See our \u003ca href=\"\/resources\/guides\/door-closer-selection-guide\"\u003edoor closer selection guide\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eFire doors\u003c\/h3\u003e\n\u003cp\u003eGlynn-Johnson's catalog says its 410 Series stop only models are classified by UL as miscellaneous fire door accessories (category GVUX), for hollow metal or wood fire doors of any rating, while its installation instructions say stop only units are permitted on many fire door applications. Confirm the 413S or 415S against your fire door's listing. On a wood fire door, the catalog allows it only where the door manufacturer's listing allows the cutout. Our \u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-80\"\u003eNFPA 80 guide\u003c\/a\u003e covers what may go on a fire door.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-files\/glynn-johnson\/information-documents\/Glynn-Johnson_Overhead_Door_Holders.Stops_Catalog_101401.pdf\" rel=\"nofollow\"\u003eGlynn-Johnson overhead door holders and stops catalog\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/us.allegion.com\/content\/dam\/allegion-us-2\/web-files\/glynn-johnson\/installation-documents\/Glynn_Johnson_410_Series_Concealed_Overhead_Holder_H_F_S_SE_Installation_Instructions_101341.pdf\" rel=\"nofollow\"\u003eGlynn-Johnson 410 Series installation instructions\u003c\/a\u003e\u003c\/p\u003e","brand":"Glynn Johnson","offers":[{"title":"Size 3 (413S): opening 27-1\/16 to 33 in on butt hinges or offset pivots","offer_id":48052860027057,"sku":"413SUS32D","price":123.0,"currency_code":"USD","in_stock":true},{"title":"Size 5 (415S): opening 39-1\/16 to 45 in on butt hinges or offset pivots","offer_id":48052860059825,"sku":"415SUS32D","price":127.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/0_477820be-c11f-4093-a290-d3cc8dfb1ddf.webp?v=1792199619"}],"url":"https:\/\/shop.usmadesupply.com\/collections\/overhead-door-stops-and-holders.oembed","provider":"US Made Supply","version":"1.0","type":"link"}