The Corbin Russwin ED5200A is the 3 hour fire rated version of Corbin Russwin's ED5200 rim exit device, from the ED5000 Series of wide stile pushpad devices, in satin stainless steel 630. This build is exit only (ANSI function 01): it has no outside trim, so the door opens from the push side only. See all our rim exit devices.
Specifications
| Model | ED5200A, 630, 36 or 48 in. Selected above |
| Function | Exit only, ANSI function 01: no outside trim |
| ANSI/BHMA | A156.3, Type 1, Grade 1, per Corbin Russwin |
| Dogging | None. Corbin Russwin does not offer mechanical dogging on fire rated devices, so the latch cannot be held open |
| Device length | 36 in fits doors 30 to 36 in wide. 48 in fits doors 36 to 48 in wide. Either can be cut to size in the field |
| Door | 1-3/4 in thick as standard, on a stile at least 4-1/2 in wide |
| Handing | Non-handed |
| Latchbolt | Stainless steel pullman type, 3/4 in throw, with a stainless steel deadlocking latch |
| Strike | Surface mounted 3/8 in diameter roller strike with a positive locking plate and shims |
| Projection | 3-1/4 in active |
| Finish | Satin stainless steel 630 (US32D) |
| Fasteners | Sex nuts and bolts, standard on Corbin Russwin's fire rated devices |
Fire doors and codes
Corbin Russwin lists its 3 hour fire rated ED5000 devices with UL and cUL as fire exit hardware for A label and lesser class doors, 4 x 8 ft single or 8 x 8 ft double, with the UL symbol on the active case cover showing the listing, and as panic hardware to UL 305. Its 3 hour listing for a pair of doors is two ED5200A devices with a removable mullion between them, and the mullion must be one of Corbin Russwin's 3 hour fire rated steel mullions: the CR972A for doors up to 7 ft 2 in high, or the CR910A, fire rated up to 8 ft. Its CR972 and CR910 mullions are panic rated only. It says its fire rated devices comply with NFPA 80, all its exit devices with the NFPA 101 Life Safety Code and the Americans with Disabilities Act, and that the California State Fire Marshal has approved this device. A field change to a fire rated opening can affect its rating, and whether an opening complies depends on the whole door, so your authority having jurisdiction decides.
What else the opening needs
Outside trim if the door must open from outside: this exit only build has none, and Corbin Russwin's trims are their own part, which we can quote. Under NFPA 80 a fire door also has to be self-closing or automatic-closing and positive latching, so the opening needs a listed closing device as well as a listed door and frame.
Documents
Corbin Russwin ED5000 Series product page
ED5000 Series catalog
ED5200(A) installation instructions
Template T30802, metal door and frame
Template T30836, wood or composite door