An exit device is the push bar on the inside of a door. This is the trim, the hardware on the outside face of that same door. It mounts through the door and works the device's latch, so it is what decides whether anyone can get back in.
What this one does
Pull plate. A pull plate for the ECL-230X opening.
Detex uses the BHMA function descriptions, and prints this one as: Entrance by trim when latch bolt is released by key. Key removable only when locked.
Specifications
| Detex part number | 03PP |
| Style | Pull Plate |
| Mounting | Two posts, 7 in apart |
| Cylinder | Rim cylinder required, not included |
| Fits | the Detex ECL-230X alarmed deadbolt |
Detex supplies 03 function trims with a cylinder bracket kit whose spring loaded tailpiece self adjusts to the door thickness.
Pull style. Fits the Detex ECL-230X alarmed deadbolt. Detex uses the BHMA function descriptions for all trims.
Fitting it
Detex designs the trim and the device mounting plate so the function can be changed by swapping the outside trim alone, without taking the exit device off the door. Confirm the device series and the door's handing before ordering.
Panic hardware requirements: IBC panic hardware. Grade testing basis: ANSI/BHMA A156.3.