The Detex Advantex 50 Series is Detex's super-heavy-duty surface vertical rod exit device for narrow stile double doors without a mullion. The top and bottom rods latch into the head and the floor, so a pair of doors can close against each other with no center post. Detex supplies every 50 Series with top and bottom rod covers and an ADA ramped bottom bolt cover, and tests it beyond 1,000,000 cycles, twice the cycling UL requires for Grade 1. This is the 36 in device for a 7 ft door, in satin stainless steel (630). Detex describes its products as assembled in America.
Specifications
| Model | 50 630 96 36X84, with the dogging code selected above: 50 HD 630 96 36X84 or 50 CD 630 96 36X84 |
| Device type | Narrow stile surface vertical rod exit device |
| Door width | Fits a 36 in (3 ft) wide door |
| Door height | Fits a 7 ft (84 in) door, with top and bottom rods and rod covers |
| Latching | Stainless steel deadlocking top latchbolt; hardened steel bottom drop bolt with ADA ramped cover |
| Strike | 96 surface strike |
| Finish | 630 (US32D) satin stainless steel, finished over stainless steel with PVD |
| Dogging | Hex dogging, Cylinder dogging, selected above. 1/8 turn |
| Listings | UL listed panic hardware (UL 305); ANSI/BHMA A156.3 Grade 1 |
| Warranty | Detex limited warranty: 10 years mechanical, 3 years electrical |
Choosing the dogging option
Dogging holds the latch retracted so the door pushes open freely during open hours. Hex dogging uses a hex key and is the Detex standard. Cylinder dogging does the same with a key, and the cylinder is not included, so order one with the device or it arrives unable to dog. Choose no dogging when the opening should stay latched at all times. Each option is the same price.
Fire-rated doors
This is the panic hardware version. Detex's fire exit hardware is a separate model with an F prefix in the part number, so do not use this device on a fire-rated opening. Outside trim is sold separately.
Related standards
Panic hardware requirements and mounting heights: IBC panic hardware. The panic hardware standard itself: UL 305. Grade 1 testing basis: ANSI/BHMA A156.3. Exit and egress rules for your occupancy: NFPA 101 and IBC Chapter 10.