{"product_id":"detex-v40-ee-48-in-delayed-egress-rim-exit-device","title":"Detex V40EEFC362899 48\" Delayed Egress Rim Exit Device","description":"\u003cp\u003eThe \u003ca href=\"\/companies\/detex\"\u003eDetex\u003c\/a\u003e V40 EE is a Grade 1 rim exit device with delayed egress built in. Push the bar and\nthe device holds the door locked for 15 seconds while a 100 decibel alarm sounds, which gives\nstaff time to respond before the door releases. It is the configuration specified for stockrooms,\nback-of-house exits, behavioral health units and retail secondary exits, where an unmonitored\nexit is a loss or safety problem. This is the 48 in device in satin aluminum. Detex describes its\nproducts as assembled in America.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV40 EE FC3 628 99 48, plus the option codes selected above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWide stile rim exit device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 in (fits a 4 ft door)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 second delayed egress, 100 dB alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCylinder dogging (CD) or no dogging (Detex code LD), selected above. Mortise cylinder not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiltered and regulated 24VDC Detex supply, included except on the without-power-supply build (Detex code PS0). Detex does not name the model in its EE package descriptions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConduit kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible 3 ft conduit kit (FC3), included on every build in this ladder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9V battery, alarm function only, during power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLatchbolt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel 3\/4 in deadlocking Pullman type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrike\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 surface strike\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e628 satin aluminum clear anodized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminum rail, stainless steel latchbolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 305 panic hardware; ANSI\/BHMA A156.3 Grade 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eHow the delay works\u003c\/h3\u003e\n\u003cp\u003eThe alarm is triggered by latchbolt movement, so the device reacts to someone actually\npushing the bar rather than to a door position switch. A fire alarm input wires in at the power\nsupply, which is how the door is released on an alarm condition. Detex rates the housing as\ntamper resistant and the 9V battery maintains the alarm, but not the delay, if power is lost.\u003c\/p\u003e\n\u003cp\u003eWhere a delayed egress device is permitted, and for how long the delay may run, is set by the\nadopted building and life safety codes for your occupancy. Start with\n\u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-101\"\u003eNFPA 101\u003c\/a\u003e and\n\u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/ibc-chapter-10\"\u003eIBC Chapter 10\u003c\/a\u003e,\nand confirm with your authority having jurisdiction before specifying.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing the power supply option\u003c\/h3\u003e\n\u003cp\u003eThe device runs on filtered and regulated 24VDC and cannot operate without a supply. The\nstandard build ships with a Detex supply, which is what a single opening needs. Detex does not\nname the model in its EE package descriptions, and its current price list introduces the PS80 as\nreplacing the 90-800 while still listing the older model, so confirm which one you receive if\nbattery backup matters: a 90-800 has no battery-charging circuit, while a PS80 can carry\nbatteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe without-power-supply build is not a way to save money on a single door.\u003c\/strong\u003e\nDetex calls it PS0, and it exists for the \u003cstrong\u003esecond leaf of a pair\u003c\/strong\u003e, where the two\ndevices share the supply that came with the first. A Detex filtered and regulated 24VDC supply is\nstill required. If this is a single opening, or you are not certain a Detex supply with spare\ncapacity is already at the door, choose the build that includes it.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing the dogging option\u003c\/h3\u003e\n\u003cp\u003eCylinder dogging holds the latch retracted so the door pushes open freely during open hours.\n\u003cstrong\u003eThe mortise cylinder is not included\u003c\/strong\u003e, so order one with the device or the unit\narrives unable to dog. If the opening should stay latched at all times, the no-dogging build\n(Detex code LD) is the same price.\u003c\/p\u003e\n\n\u003ch3\u003eRelated hardware and standards\u003c\/h3\u003e\n\u003cp\u003ePanic hardware requirements and mounting heights:\n\u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/ibc-panic-hardware\"\u003eIBC panic hardware\u003c\/a\u003e.\nGrade 1 testing basis:\n\u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/ansi-bhma-a156-3\"\u003eANSI\/BHMA A156.3\u003c\/a\u003e.\nThe panic hardware standard itself:\n\u003ca href=\"\/resources\/building-codes-standards\/emergency-life-safety\/ansi-ul-305\"\u003eUL 305\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments and downloads\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.detex.com\/products\/life-safety-security-door-hardware\/value-series\/delayed-egress-ee\/\" rel=\"nofollow\"\u003eDetex Delayed Egress (EE) product page\u003c\/a\u003e ·\n\u003ca href=\"https:\/\/www.detex.com\/products\/life-safety-security-door-hardware\/value-series\/v40\/\" rel=\"nofollow\"\u003eDetex V40 series page\u003c\/a\u003e\u003c\/p\u003e","brand":"Detex","offers":[{"title":"Satin Aluminum \/ Cylinder dogging \/ With power supply","offer_id":47932487696561,"sku":"V40EEFC3CD6289948","price":2207.0,"currency_code":"USD","in_stock":true},{"title":"Satin Aluminum \/ Cylinder dogging \/ Without power supply","offer_id":47932487729329,"sku":"V40EEFC3CD6289948PSO","price":2050.0,"currency_code":"USD","in_stock":true},{"title":"Satin Aluminum \/ No dogging \/ With power supply","offer_id":47932487762097,"sku":"V40EEFC3LD6289948","price":2207.0,"currency_code":"USD","in_stock":true},{"title":"Satin Aluminum \/ No dogging \/ Without power supply","offer_id":47932487794865,"sku":"V40EEFC3LD6289948PSO","price":2050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/V40EE-composite_b39d0dc1-25fd-4996-ae60-0ee2cc0f31a6.webp?v=1789495085","url":"https:\/\/shop.usmadesupply.com\/products\/detex-v40-ee-48-in-delayed-egress-rim-exit-device","provider":"US Made Supply","version":"1.0","type":"link"}