The Detex V50 is a heavy-duty surface vertical rod exit device from Detex's Value Series, for single doors and pairs of doors without a mullion. The top and bottom rods latch the door into the head and the floor, so a pair can close against each other with no center post. It has a stainless steel 3/4 in deadlocking top latchbolt and a ribbed aluminum rail, and Detex rates it to withstand over 1,400 lbs of static pull force. This is the 36 in device for a 7 ft door, in black (711) or aluminum (628). Detex describes its products as assembled in America.
Specifications
| Model | V50 711 96 36X84 (black) or V50 628 96 36X84 (aluminum), with the dogging code selected above (HD, CD or LD): V50 HD 711 96 36X84, V50 CD 711 96 36X84, V50 LD 711 96 36X84, V50 HD 628 96 36X84, V50 CD 628 96 36X84 or V50 LD 628 96 36X84 |
| Device type | Surface vertical rod exit device |
| Door width | Fits a 36 in (3 ft) wide door |
| Door height | Fits a 7 ft (84 in) door, with top and bottom rods |
| Latchbolt | Stainless steel 3/4 in deadlocking top latchbolt |
| Strike | 96 surface strike |
| Rail | Heavy-duty ribbed aluminum |
| Finish | Black (711): black all over. Aluminum (628): black end pieces and push pad on an aluminum rail. Selected above |
| Dogging | Hex dogging (Detex standard), cylinder dogging or no dogging, selected above. 1/8 turn |
| Handing | Handed, field reversible |
| Listings | UL listed panic hardware (UL 305); ANSI/BHMA A156.3 Grade 1. Detex states it meets ADA requirements |
| Warranty | Detex limited warranty: 10 years mechanical, 3 years electrical |
Choosing the dogging option
Dogging holds the latch retracted so the door pushes open freely during open hours. Hex dogging uses a hex key and is the Detex standard. Cylinder dogging does the same with a key, and the cylinder is not included, so order one with the device or it arrives unable to dog. Choose no dogging when the opening should stay latched at all times. All three are the same price.
Fire-rated doors
This is the panic hardware version. Detex's fire exit hardware is a separate model with an F prefix in the part number, so do not use this device on a fire-rated opening. Outside trim is sold separately.
Related standards
Panic hardware requirements and mounting heights: IBC panic hardware. The panic hardware standard itself: UL 305. Grade 1 testing basis: ANSI/BHMA A156.3. Exit and egress rules for your occupancy: NFPA 101 and IBC Chapter 10.