The Glynn-Johnson 410 Series is a concealed overhead holder and stop for medium to light duty doors. The channel is mortised into the top of the door and the jamb bracket into the frame, so when the door is closed the whole unit is hidden. When the door is open, only the arm and the jamb bracket show. The 414H holds the door open automatically at a preset angle and the 414S only stops it. Both are size 4, for door openings of 33-1/16 to 39 in, in 630 (US32D) satin stainless steel, and non-handed.
Specifications
| Model | 414H (hold open) or 414S (stop only), size 4, 630 satin stainless steel. Selected above |
| 414H hold open | The hold open engages automatically when the door opens to its preset angle. It cannot be switched off, so the door is always held open there. Hold open tension adjusts with an Allen wrench. Glynn-Johnson says it meets the 250,000 test cycles required for Grade 1 |
| 414S stop only | Stops the door with a shock absorbing spring, without holding it open |
| Angle | Set at installation anywhere from 85 to 110 degrees with Glynn-Johnson's templates. The shock absorber gives about 5 to 7 degrees, so where a wall or another door is in the way, set the stop that much short of it (dead-stop templating) |
| Sizing | Size 4: door opening 33-1/16 to 39 in. Glynn-Johnson sizes by the door opening, measured jamb to jamb, not by the width of the door. The opening ranges here are for doors hung on butt hinges or offset pivots. Center hung doors use a different chart, so check the catalog for those. |
| Mounting | Concealed: channel mortised into the top of the door, jamb bracket mortised into the frame. Single or double acting doors. Works with most surface applied door closers. Interior applications |
| Option | SOC: pin-in-socket security screws for mounting the jamb bracket, supplied instead of the standard screws |
What else the opening needs
Door and frame preparation. Being concealed, it needs the door and frame mortised to Glynn-Johnson's template, and its installation instructions give the mortises and mounting holes. Reinforcement. Glynn-Johnson stresses that the door and frame must be reinforced to anchor an overhead stop. For metal doors and frames Glynn-Johnson recommends reinforcement at least 3/16 in thick, 1-1/2 in wide and 12 in long. For wood doors and frames, make sure there is enough material to anchor it. A door closer, if the door has one. Glynn-Johnson recommends an overhead stop on every door with a closer, because a closer is not a door stop. See our door closer selection guide.
Fire doors
Glynn-Johnson's catalog says its 410 Series stop only models are classified by UL as miscellaneous fire door accessories (category GVUX), for hollow metal or wood fire doors of any rating, while its installation instructions say stop only units are permitted on many fire door applications. That covers the stop only 414S: confirm it against your fire door's listing. On a wood fire door, the catalog allows it only where the door manufacturer's listing allows the cutout. The 414H's hold open is mechanical and cannot be switched off, and Glynn-Johnson's instructions say mechanical hold-open devices that require manual release are not permitted on any fire door. Our NFPA 80 guide covers what may go on a fire door.