The Glynn-Johnson 90S is the stop-only model of the 90 Series, which Glynn-Johnson calls its most rugged holders and stops, for heavy duty applications. It stops the door at a set angle, protecting the door, frame, hinges, closer and nearby walls, and a shock absorbing spring cushions the stop. The channel is thru-bolted to the top of the door with sex bolts and the jamb bracket mounts on the face of the frame, so neither needs to be mortised in. This is 630 (US32D) satin stainless steel and non-handed. This listing has four sizes. Glynn-Johnson also makes a size 3 (903S) for openings of 27-1/16 to 33 in.
Specifications
| Model | 902S, 904S, 905S or 906S, 630 satin stainless steel. Selected above |
| Function | Stop only, with a shock absorbing spring that gives about 5 to 7 degrees past the stop point |
| Stop angle | Set at installation anywhere from 85 to 110 degrees with Glynn-Johnson's templates. Where a wall or another door is in the way at 110 degrees or less, Glynn-Johnson recommends dead-stop templating, set 5 to 7 degrees short of the point the door must not pass |
| Sizing | Glynn-Johnson sizes by the door opening, measured jamb to jamb, not by the width of the door. The opening ranges here are for doors hung on butt hinges or offset pivots. Center hung doors use a different chart, so check the catalog for those. |
| Mounting | Surface mounted. Channel thru-bolted to the door with sex bolts, jamb bracket on the face of the frame. For single acting doors, works with most surface applied door closers. Interior or exterior doors |
| Options | 90J angle jamb bracket for hinge side or flush transom mounting. 90 SHIM1, SHIM2 or SHIM3 blade stop shims (1/4, 1/2 or 3/4 in). SOC: pin-in-socket security screws for the door and jamb brackets, supplied instead of the standard screws |
| Standards cross reference | Glynn-Johnson cross references the 902 to 906 S to BHMA C02541 (ANSI/BHMA A156.8) and federal specification 1161A |
What else the opening needs
Reinforcement. Glynn-Johnson stresses that the door and frame must be reinforced to anchor an overhead stop. For metal doors and frames Glynn-Johnson recommends reinforcement at least 3/16 in thick, 1-1/2 in wide and 12 in long. For wood doors and frames, make sure there is enough material to anchor it. A door closer, if the door has one. Glynn-Johnson recommends an overhead stop on every door with a closer, because a closer is not a door stop. See our door closer selection guide. A hold-open, if wanted. This is stop only. The 90H holds the door open and is a different part.
Fire doors
Glynn-Johnson says its stop-only models are classified by UL as miscellaneous fire door accessories (category GVUX), for hollow metal or wood fire doors of any rating. Our NFPA 80 guide covers what may go on a fire door.