The LCN 8310-853T and 8310-836T are hard wired, low voltage push plate actuators: the button a person presses to open a door that has an automatic operator. Both have a stainless steel touch plate engraved with a blue-filled wheelchair symbol and the words Push to Open. The 8310-853T is a 4-3/4 in square plate for a wall or a bollard. The 8310-836T is a full length plate with a 36 x 6 in activation surface, which LCN designed to increase accessibility for people entering in a wheelchair. See all our automatic door operators.
Specifications
| Model | 8310-853T (wall mount, 4-3/4 in square) or 8310-836T (full length, 36 x 6 in). Selected above |
| Type | Hard wired, low voltage actuator (switch) for an automatic door operator. Wireless versions are separate models (8310-853TWP and 8310-836TW) and are not these |
| Plate | Stainless steel touch plate. Engraved blue-filled wheelchair symbol, which LCN says conforms to most accessibility codes, plus engraved Push to Open text |
| 8310-853T mounting | Mounts in a flush or surface mount box on a vertical surface near the door, or on an LCN 8310-866 bollard post. LCN also allows a single gang electrical box or a 4 x 4 in double gang box (by others). LCN describes vandal resistant mounting and a weather resistant switch as standard |
| 8310-836T mounting | Mounts to a wall or a bollard. On a wall, LCN's instructions call for a junction box mounted flush with the wall, its center no less than 34-3/8 in above the finished floor (or the top of the baseboard or cove). LCN says the full length plate is designed to meet California building codes |
| Works with | LCN automatic operators, including the 4640 Series Auto Equalizer (LCN's 4600 instructions say it is compatible with all LCN 8300 series actuators) |
What else the opening needs
An operator. An actuator only sends the signal. It needs an automatic door operator, and LCN sells its actuators separately from its operators. A box for the square plate. The 8310-853T goes into a box that is not included: LCN's 8310-867S surface box or 8310-867F flush box, an electrical box by others, or a bollard. Low voltage wiring from the plate to the operator's control box, run by your installer. Usually two. LCN's sample applications show one actuator inside the door and one outside.
Documents
LCN Automatic Operators catalog (actuators and accessories section)