NGP GapGuard GAP90 components: a gray steel stop extender with a UL mark, a gray intumescent seal and a charcoal silicone smoke seal
NGP drawing of the GAP90 installed on a door frame stop, closing a head or jamb gap of up to 9/16 in between door and frame
  • Load image into Gallery viewer, NGP GapGuard GAP90 components: a gray steel stop extender with a UL mark, a gray intumescent seal and a charcoal silicone smoke seal
  • Load image into Gallery viewer, NGP drawing of the GAP90 installed on a door frame stop, closing a head or jamb gap of up to 9/16 in between door and frame

NGP GapGuard GAP90 Fire Door Head and Jamb Gap Solution

Regular price
$521.00
Sale price
$521.00
Regular price
Sold out
Unit price
per 

The NGP GapGuard GAP90 closes an excessive gap between a fire door and its frame at the head or jambs, without replacing the door or frame. NGP states it is UL certified for clearances over 1/8 in, up to 9/16 in, on hollow metal fire doors rated up to 180 minutes and wood fire doors rated up to 90 minutes. Each piece is three parts that install together on the frame: a steel stop extender, an intumescent seal and a silicone smoke seal. See all our door seals and gasketing.

Specifications

Model NGP GAP90, gray. Length selected above
Gap it fixes Head or jamb clearance over 1/8 in, up to 9/16 in
Fire rating Hollow metal fire doors up to 180 minutes; wood fire doors up to 90 minutes, per NGP
What is in it 9945 steel stop extender (16 gauge, gray primer, embossed with the UL mark, with #10 x 1 in TEK screws), 9400GR intumescent seal (gray) and 5050C silicone bulb smoke seal (charcoal), per NGP's catalog
Smoke seal NGP states the 5050C is smoke and draft control gasketing (Category H) tested to UL 1784, meeting NFPA 105 and IBC requirements for use on S label doors
Handing Non-handed
Lengths Sold here in 36, 48 and 84 in, cut to fit on site. NGP also makes a 96 in length, which we quote

Which lengths a door takes

Each piece covers one edge of the frame and is cut to fit, so order one piece for the head and one for each jamb that has an excessive gap: on a 3 ft x 7 ft single door, that is a 36 in piece for the head and an 84 in piece for each jamb. NGP requires every component of the GAP90 to be installed.

What else you may need

NGP says one or more strike shims (9275 for a 4-7/8 in ASA strike, 9225 for a 2-3/4 in T strike) may be needed for the latch bolt to engage properly. On a door with a parallel arm closer, NGP points to its 9990 top gap solution for the head, and its instructions have you cut the stop extender and leave it off at a closer shoe or exit device strike. On the hinge edge of a category B wood door, NGP requires a UL certified category G edge seal. We quote strike shims and edge seals: ask us.

Fire rated doors

NGP states the GAP90 is certified by UL to ANSI/UL 10C (positive pressure) and to ANSI/UL 10B and CAN/ULC-S104, for use in the US and Canada, and that it complies with IBC, NFPA 80 and NFPA 252 for hollow metal and wood fire doors. NGP calls it a positive pressure tested miscellaneous fire door accessory.

The door's label and listing, NGP's installation instructions and your authority having jurisdiction decide whether a repair is accepted. Measure the gap between door and frame on the pull side of the door, where an NFPA 80 inspection checks it. See our NFPA 80 page for the clearance limits.

Installing

NGP's instructions: fasten the stop extender to the frame stop soffit with the TEK screws in every hole, then apply the intumescent seal and the smoke seal. The frame must be above 60°F for the adhesive to bond. Clean the frame first; wax coated or high gloss paint may need roughening. Do not cover the frame's fire label, press the seals down firmly (about 15 lb) along their full length, do not lift and relocate them, and check the door still closes and latches. The adhesive has a one year shelf life stored at 75°F and 50% relative humidity or less.

Documents

NGP GAP90 installation instructions
NGP GAP90 cut sheet
NGP GAP90 product page
NGP GapGuard catalog