The SDC ExitCheck 1511S is an integrated delayed egress magnetic lock for a single door. The electromagnet holds the door closed on top of the door's own latching hardware. With SDC's built-in trigger nothing is added to the exit device or lockset; external activation, for a latchless door or where preferred, adds a switch kit in the exit device, a latch monitoring strike or an egress bar, plus a power transfer. When someone pushes to leave, the lock sounds an alarm, counts down on a digital display with spoken instructions, and releases after the delay, 15 seconds on every build here and 30 seconds on the selectable build where the authority having jurisdiction has approved it. A signal from the fire alarm system releases it at once. This is SDC's 628 dull aluminum finish with the built-in keyswitch reset, in four builds: three operation modes, and the NA mode with or without a door position status output. SDC describes its delayed egress products as designed, engineered and built in America. See all our magnetic locks.
Specifications
| Model | 1511SNAKV (NA mode), 1511SNDKV (ND mode), 1511SNCKV (NC mode), 1511SNAKVD (NA mode with door position status output). Selected above |
| Lock type | Integrated delayed egress electromagnetic lock for a single door. The lock body mounts to the frame header, the armature to the door |
| Holding force | 1,650 lb, per SDC's datasheet |
| Delay and mode | NA: SDC's NFPA 101 mode. Delay selectable 15 or 30 seconds, nuisance delay 1 or 2 seconds, manual reset after an alarm, lock on power-up selectable locked or unlocked. ND: NFPA 101 mode with a fixed 15 second delay, selectable nuisance delay, manual reset, lock on power-up selectable. NC: SDC's California Building Code mode, fixed 15 second delay, selectable nuisance delay, manual reset, and the lock powers up unlocked until it is reset at the door |
| Warning | Digital countdown display, alternating spoken message and spoken countdown (a male security message or a female safety message, or tone only, selected in the field), and an alarm tone |
| Activation | Built-in trigger with an adjustable door movement sensor. An external trigger input takes an egress bar, a latch monitoring strike or an exit device switch kit |
| Reset and bypass | Integrated three-position keyswitch for reset and bypass; remote reset, request-to-exit and instant bypass override inputs |
| Power | 12 or 24 VDC (plus or minus 10 percent), auto-sensing. 820 mA at 12 VDC, 500 mA at 24 VDC. Power supply not included; SDC's instructions call for a UL 294 listed supply |
| Outputs | Lock secure relay and alarm relay, SPDT, each rated 1 A at 30 VDC in SDC's installation instructions. Door position status output on the D build: SPDT, 250 mA at 30 VDC |
| Fire alarm input | Dry, normally closed contact from the fire alarm or smoke detection system, wired to the lock's own FP terminals |
| Size | Housing 11 x 2-3/4 x 2-5/8 in. Armature 7-3/8 x 2-3/8 x 9/16 in |
| Weight | 14 lb, per SDC's datasheet |
| Finish | 628 dull aluminum |
| Environment | Interior applications only. 0 to 49 C, 85 percent relative humidity, non-condensing |
| Systems | SDC states the ExitCheck is compatible with access control systems and with wandering patient and infant tracking systems |
What else the opening needs
A power supply. None is included. SDC's instructions call for a UL 294 listed supply, 12 or 24 VDC; SDC publishes a supply capacity chart for its delayed egress locks, and the draw above sizes it. The fire alarm tie-in. The fire alarm or smoke detection system lands on the lock itself, on its FP terminals, as a dry normally closed contact. It is a separate connection to the building's fire alarm system, so put it in the quote and the commissioning scope. The right latch condition. SDC's built-in trigger works with latching hardware that keeps the door closed and rigid, locked on the outside and free on the inside: releasing the latch and pushing moves the door slightly and starts the cycle. A latchless door, such as a glass or herculite door, needs an SDC egress bar (MSB550 or PSB560) or another external trigger, plus a power transfer. Brackets where the stop is shallow. SDC sells filler plates (FP11V to FP15V) and angle brackets (AB11V to AB14V) for frames without enough flat mounting surface. The door sign. The package list in SDC's instructions shows the lock and mounting plate, the armature with its trigger and base, a template and two screw packs, and no sign, so plan to source the sign your code requires. Keys. SDC's documents do not say whether keys ship with the built-in keyswitch; ask us before you order if that matters to the job.
Listings
SDC lists the 1511S to UL 294 (access control system units), to UL 10B and UL 10C (fire tests of door assemblies), ULC-S104 and ULC-S533 (egress door securing and releasing devices), and under NFPA 101 special locking arrangements, NFPA 1-UFC, the IBC and IFC delayed egress lock provisions and SBC, with California State Fire Marshal listing 3774-0324:0103. SDC lists the NC build to the California Building Code's special egress control device provisions. SDC's own footnote applies: all installations must be approved by the local authority having jurisdiction. SDC's installation instructions place it under the UL categories for auxiliary locks (GWXT) and special locking arrangements (FWAX), not panic hardware: it does not latch the door, and the listings SDC publishes for it do not include UL 305.
Where delayed egress is allowed
Whether a delayed egress lock is permitted on your opening, and on what conditions, is decided by the building and life safety codes your jurisdiction has adopted and by your authority having jurisdiction, not by the hardware. Our delayed egress locking guide covers what to confirm before you order. The underlying codes are NFPA 101 and IBC Chapter 10.