{"product_id":"sdc-lr100-quietduo-electric-latch-retraction-kit","title":"SDC LR100 QuietDuo Electric Latch Retraction Kit","description":"\u003cp\u003eThe \u003ca href=\"\/companies\/security-door-controls\"\u003eSDC\u003c\/a\u003e QuietDuo LR100VDK is a motorized electric latch retraction kit that goes inside an existing Von Duprin 98, 99, 33A or 35A Series exit device. When it is energized, its motor retracts the device's latch and pulls the pushpad into the dogged (depressed) position, so an access control system, a remote control device or a building automation system can release the door for a moment or hold it free for push and pull operation. SDC states that the exit device always provides uninhibited egress. SDC makes an LR100 kit for each exit device it supports; this listing is the Von Duprin kit for 36 to 48 in openings. See all our \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/exit-device-parts\"\u003eexit device parts\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLR100VDK, SDC's field install kit for Von Duprin devices in 36 to 48 in openings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePer SDC's application chart: rim 98, 99, 33A and 35A; surface vertical rod 9827, 9927, 3327A, 3527A, 9857 and 9957; concealed vertical rod 9847, 9947, 3347A, 3547A, 3348A and 3548A; mortise 9875 and 9975\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNot for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVon Duprin 22 Series devices, which take SDC's LR100VDK-22 or LR100VDK-22V2 kits, or 30 in openings, which take the LR100VDK-EM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotorized latch retraction and dogging: the latch retracts and the pushpad pulls down together, for momentary or sustained release. SDC says a motor draws less current, runs quieter and lasts longer than a solenoid, and lists the kit as compatible with low energy operators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC, plus or minus 10 percent. 1.5 A inrush, 200 mA continuous. Red (+) and black (-) leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField installed as one unit inside the device rail, behind the access cover. SDC's instructions start by removing the device's mechanical dogging assembly. On vertical rod devices the rods are disconnected from the device head while the kit goes in, then reconnected and adjusted with the kit energized and the pushpad dogged down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCut-down devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSDC's note: a 42 or 48 in device cut down to fit a 36 in or smaller opening may not have room for the standard kit, so check the distance from the end of the touchpad to the end rail first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePairs of doors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSDC states that no door sequencer is required for a pair of manual doors when the kits are connected to a suitable power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included. SDC makes separate request-to-exit and latch status monitoring kits for Von Duprin devices; its LR100 datasheet lists which fit each series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eWhat else the opening needs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eA 24 VDC power supply.\u003c\/strong\u003e None is included. SDC's LR100 datasheet names its 602RF for a single door with this kit and says SDC 602 power controllers accommodate the 1.5 A inrush; see our \u003ca href=\"\/architectural\/door-hardware\/commercial-door-hardware\/access-control-power-supplies\"\u003eaccess control power supplies\u003c\/a\u003e. For a pair of doors released together SDC specifies its 602RFUR1 or 634RF instead, and with another maker's supply it recommends a linear, regulated and filtered supply rated at least 2 A per kit. \u003cstrong\u003eA control.\u003c\/strong\u003e The kit runs whenever its 24 VDC is switched on, by an access control system's relay, a remote control device or a building automation system. \u003cstrong\u003eWiring onto the door.\u003c\/strong\u003e The leads run from the device through the door to the supply, so the circuit has to cross from the door to the frame, usually through an electrified hinge or a power transfer. \u003cstrong\u003eThe right device.\u003c\/strong\u003e The kit retrofits an existing Von Duprin device: check its series and the opening width against the chart above before you order.\u003c\/p\u003e\n\n\u003ch3\u003eListings\u003c\/h3\u003e\n\u003cp\u003eSDC lists its LR100 kits to UL 305 (panic hardware), UL 10C (positive pressure fire tests of door assemblies), ULC-S104 and ANSI\/BHMA A156.3 Grade 1, and describes them as working with panic and fire rated mechanical exit devices. SDC's UL listings page places all LR100 and LR100-EM units under accessories for single-point locks and latches and fire exit hardware (GWVW), fire exit hardware (GXHX) and panic hardware (FVSR). The kit is added to an exit device rather than being one, so confirm with your authority having jurisdiction that the device with the kit installed suits the opening, particularly a fire rated one.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sdcsecurity.com\/docs\/DS-LR100.pdf\" rel=\"nofollow\"\u003eSDC LR100 datasheet (DS-LR100)\u003c\/a\u003e ·\n\u003ca href=\"https:\/\/www.sdcsecurity.com\/docs\/INST-LR100VDK.pdf\" rel=\"nofollow\"\u003eSDC LR100VDK installation instructions\u003c\/a\u003e ·\n\u003ca href=\"https:\/\/www.sdcsecurity.com\/products\/LR100-Series-Retrofit-Electric-Latch-Retraction-Kits\" rel=\"nofollow\"\u003eSDC LR100 product page\u003c\/a\u003e ·\n\u003ca href=\"https:\/\/www.sdcsecurity.com\/ul-listings\" rel=\"nofollow\"\u003eSDC UL listings\u003c\/a\u003e\u003c\/p\u003e","brand":"SDC","offers":[{"title":"Von Duprin 98\/99 and 33A\/35A Series (LR100VDK)","offer_id":48106439475377,"sku":"LR100VDK","price":503.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0529\/5269\/4961\/files\/0_4b51b5fd-abfb-4115-a370-48ca5400983e.webp?v=1793202503","url":"https:\/\/shop.usmadesupply.com\/products\/sdc-lr100-quietduo-electric-latch-retraction-kit","provider":"US Made Supply","version":"1.0","type":"link"}